![]() ![]() To use an interface, it mustīe physically enabled in FXOS and logically enabled in the ASA. You can physically enable and disable interfaces, as well as set the interface speed and duplex. You can manually remove the old interface configuration in the ASA OS. The ASA configuration retains the original commands so that you can make any necessary adjustments removing an interfaceįrom the configuration can have wide effects. If you remove an interface in FXOS (for example, if you remove a network module, remove an EtherChannel, or reassign an interface to an EtherChannel), then Make the interface changes in FXOS on the standby unit, and then make the same changes on the active unit. If you change the interfaces in FXOS after you enable failover (by adding or removing a network module, or by changing the EtherChannel configuration, for example), The Firepower 2100 has support for jumbo frames enabled by default. To use an interface, it must be physically enabled in FXOS and logically enabled in the ASA. You can manage physical interfaces in FXOS. Inventory-Lists the components installed in the chassis and provides relevant details for those components, such as: component name, number of cores, installation location, operational status, operability, capacity, power, thermal, serial number, model State, image version, and management IP address. You can click on any interface to see a graphical representation of the number of input and output bytes for that interfaceĭevices- Shows the ASA, and provides the following details: device name, device state, application, operational state, administrative Of received bytes, and number of transmitted bytes. Interfaces-Lists the interfaces installed in the system and shows the interface name, operational status, administrative status, number Other users know that the fault is currently being addressed. If a user is working on a resolution for a specific fault, they can acknowledge the fault to let Once the underlying cause of the fault has been addressed, the fault will automatically be cleared from the listing during You can click on any of the faults to see additional details for the fault or to acknowledge the fault. ![]() You can also see whether the fault has been acknowledged or not. For each fault that is listed, you can see the severity, a description of the fault, the cause, the number of occurrences,Īnd the time of the most recent occurrence. The faults are sorted by severity: Critical, Major, Minor, Warning,Īnd Info. The system provides the following detailed status information for the chassis:įaults-Lists the faults that have been generated in the system. Summary area for the information you want to view. You can see a summaryįor each of those sections above the table and you can see additional details for each of those sections by clicking on the The status information is broken up into these sections: Faults, Interfaces, Devices, and Inventory. Shown in the Visual Status Display to get additional information such as interface name, speed, type, admin state, and operationalĭetailed Status Information-Below the Visual Status Display is a table containing detailed status information for the chassis. That are installed in the chassis and provides a general status for those components. Visual Status Display-Below the Device Information section is a visual representation of the chassis that shows the components Uptime Information Icon-Hover over the icon to see uptime for the chassis and for the ASA security engine. Operational State-Shows the operable status for the chassis.Ĭhassis uptime-Shows the elapsed time since the system was last restarted. Version-Shows the ASA version number running on the chassis. IP address-Shows the management IP address assigned to the chassis. To change the chassis name, use the FXOS CLI scope system / set name command. ![]() By default, the name is firepower- model, for example, firepower-2140. The Overview tab provides the following elements:ĭevice Information-The top of the Overview tab contains the following information about the Firepower 2100:Ĭhassis name-Shows the name assigned to the chassis. On the Overview tab, you can easily monitor the status of the Firepower 2100. Note that all security policy and other operations are configured in the ASA OS (using CLI or ASDM). You can use the GUI chassis manager or the FXOSĬLI to configure these functions this document covers the chassis The Firepower 2100 runs FXOS to control basic operations of the device. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |